¤¤¤å

¦w±¶­Û


¦w±¶­Û¬ì§Þ¤½¥q(Agilent Technologies)¬O±qHP´f´¶¬ì§Þ¤½¥q¤À³Î¦Ó¦¨¥ßªº·s¤½¥q¡A¨ä¤Æ¾Ç¤ÀªR¨Æ·~¸s(Chemical Analysis Group)¥D­n±q¨Æ©ó¤ÀªR»ö¾¹¤Î¬ÛÃö®ø¯Ó«~©M¹s¥ó¤§¥Í²£»s³y¡A¨Ã¬ãµo·s¤ÀªR§Þ³N©M°â«áªA°È¡C
©Ò¥Í²£¤§¥D­n¤ÀªR»ö¾¹¬°:®ð¬Û¼hªR»ö(Gas Chromatograph system)¡B®ð¬Û¼hªR½èÃлö(Gas Chromatograph/Mass Selective Detector)¡B®ð¬Û¼hªR­ì¤l©ñ®g¥úÃлö(Gas Chromatograph/ Atomic Emission Detector)¡B²G¬Û¼hªR»ö(Liquid Chromatograph system)¡B²G¬Û¼hªR½èÃлö(Liquiid Chromatograph / Mass Selective Detector)¡B¤ò²Ó¹qªa¼hªR»ö(Capillary Electrophoresis system)¡B¤ò²Ó¹qªa¼hªR½èÃлö(Capillary Electrophoresis/Mass Selective Dector)¡Bµµ¥~¥ú¢A¥i¨£¥ú¥úÃлö(UV/Vis Spectrometer)¡B·PÀ³¦¡¹q¼ß½èÃлö(ICP/MS)¡C
¨ä¦æ·~À³¥Î¬Û·í¼sªx,¦p·Òªo¥Û¤Æ¡B°ª¤À¤l»E¦Xª«¡BÀô¹Ò¦Ã¬V¡B¹AÃÄ¡B­¹«~¡B¬r«~ÀݥΡBÁ{§É¡B¥Í¤Æ¡BÃÄ«~¤Î¥b¾ÉÅé¤ÀªR¡A¨ä¤£¶È´£¨Ñ¤ÀªR»ö¾¹,¨Ã¬ãµo¦UºØ¤ÀªR§Þ³N¡C
¬°´£¨Ñ¨Ï¥ÎªÌ§ó¶K¤ßªºªA°È¡A¤]»s³yª«¬ü»ù·Gªº®ø¯Ó«~¡A¥]¬A®ð¬Û¼hªRºÞ(Pack/Capillary Column)¡B²G¬Û¼hªRºÞ(HPLC Column)¡B¦U¦¡¦U¼Ëª`®g°w(Syringe)¤Î¼Ë«~²~(Vial)..µ¥¡C
¡ôTOP

Frontier


»s³y¤Î¬ãµo»ö¾¹©M§Þ³NÀ³¥Î©ó°ª¤À¤l»E¦Xª«¤ÀªR¡A¨ä©Ò¥Í²£¤§¼öµõ¸Ñ»ö(Double Prolyzer)¨ã¦³«e©Ò¥¼¦³ªºÀu¶V©Ê¯à¡A¨ä¹ï½ÆÂø¼Ë«~ªº©w©Ê¤ÀªR¦p©TÅé¡B²GÅé¡A´£¨Ñ¤F¬Û·í«K§Qªº¤u¨ã¡A­Y·f°t®ð¬Û¼hªR½èÃлö¤Î¨ä¯S¦³ªº°ª¤À¤l»E¦Xª«½èÃЮw¡A¹ï©ó¥¼ª¾ª«ªºÅ²©w´£¨Ñ¬Û·í­«­n¤Î¦³»ù­Èªº°T®§¡A¦Ó¥B¨äÀu²§ªº¦A²{©Ê,¤j´T´£ª@¼öµõ¸Ñ©w¶q¤§·Ç½T©Ê¡C
¥t¥~¨ä»s³yªº¤£ù׿û¤ò²Ó¼hªRºÞ(Stainless Steel Capillary Column)¡A¨Ï¥Î¯S®íªºBonding§Þ³N¡A¨Ï¨äUltra Alloy¤ò²Ó¼hªRºÞ¨ã¦³¤ñ¤@¯ëFused Silica¤ò²Ó¼hªRºÞ­@§ó°ªªº·Å«×¡A¨Ò¦pHP-1ªº³Ì°ª·Å«×325¢J¡A¦ýUA+ -1ªº³Ì°ª·Å«×¬°380¢J¡A¥i¤j´T´£ª@¤ÀªRÀ³¥Î½d³ò¡C
¡ôTOP

analytical-controls


»s³y¤Î¬ãµo¦UºØ¸Ñ¨M¤è®×(Total Solution)¥H²Å¦X¥Ûªo·Ò»s¤ÀªR¤§»Ý¨D¡A¨ä´£¨Ñªº¸Ñ¨M¤è®×¥]¬A»ö¾¹µwÅé¡B¤ÀªR¤èªk¤Îµ²ªG­pºâ¡C©Ò´£¨Ñªº¤ÀªR»ö¾¹§t·§¡G
1. ®ðÅé¡G¤ÑµM®ð¤ÀªR(Nature Gas)¡B¥Ûªo®ð¤ÀªR(Refinery Gas)¡B²G¤Æ¥Ûªo®ð¤ÀªR(Liquified
Petroleum Gas)¡B¯S®í®ðÅé¤ÀªR,¦p²¸¤Æª«¡C
2. ¥Ûªo¸£(Naphtha)¢A¨Tªo(Gasoline)¡GReformulyzer(ASTM D6293)¡BFast Total Olfins Analyzer(ASTM D629)¡BPIONA analyzer¡BDetail Hydrocarbon Analyzer with Oxygenate,DHAX¡BDetail Hydrocarbon Analyzer,DHA¡BOxygenate analyzer(ASTM D4815¡BD5599)¡BAromatics Analyzer(ASTM D3606¡BD5580)¡C
3. °ªªmª«¤Î»]ÃH(Crude Oil/Distillates)¡G¼ÒÀÀ»]ÃH,SIMDIS(ASTM D3710¡BD2887¡B2887 extend¡BHigh Temperature)¡BSIMDIS/AED¡BMiddle Distillate Analyzer(MDA),SFC(ASTM D5186),HPLC(IP391)¡BHeavy Distillate Analyzer(HAD),HPLC Distillate Analyzer¡C
¡ôTOP

Gerstel


¥D­n²£«~¬°Programmable Temperatuer Vaporizer(PTV)¡BThermal Desorption System(TDS)¡BStir Bar Sorptive Extraction (SBSE)¡A¨äÀ³¥Î¦p¤U¡G
1. PTV¡G¦w¸Ë©ó®ð¬Û¼hªR»ö(Gas Chromatograph system)¡A,¥i¤j¶qª`¤J¼Ë«~¥H´£°ªÆF±Ó«×¡A¨Ã¥i¿ï·f¨ä°t¥ó¥i¦³§N¾®¥\¯à(Cryfocusing)¡C.
2. TDS¡G®ðÅé§lªþ/¼ö²æªþ¨t²Î¡A¨Ã¥i§@§Y®ÉªÅ®ðºÊ´ú(On-Line Analysis)¡A¨Ã´£¨Ñ¦U¦¡¦U¼Ë°t¥ó¡A¥H¤ÀªR¤£¦P¼Ë«~¡C
3. SBSE¡G¦bÅͩմÎ(Stir Bar)¤W¶î©Ù(coating) polydimethylsiloxane(PDMS)¡A¥u»Ý±NÅͩմΩñ¸m©ó²GºA¼Ë«~¤¤ÅͩռƤÀÄÁ¡A¨ä§Y¥i§lªþ¦³¾÷¦¨¥÷¡A¦A©ñ¸m©óTDS¨t²Î§Y¥i±o¨ì¤ÀªRµ²ªG¡A§K°£¼Ë«~µÑ¨úªº³Â·Ð¡A ¨ä­ì²z»PSolid Phase Micro Extraction(SPME)¬Û¦ü¡A¦ý¨äÆF±Ó«×¤ñSPME°ª1000­¿¥H¤W¡A½u©Ê½d³ò(Linear Dynamic Range)¤]¸û¦n«Ü¦h¡C
¡ôTOP
Copyright(c) 2003 by Great Engineering Technology Corp.
ºô­¶ª©Åv¬°¥»¤½¥q©Ò¦³¡A½Ð¤Å¥ô·NÂà¸ü